![background image](http://html.mh-extra.com/html/brother/mfc-j6920dw/mfc-j6920dw_service-manual_17375317.webp)
5-46
Confidential
Head Calibration Data Backup/Restoration Procedures
Backup procedure
(1) Press the
6
and
8
keys in this order in the initial stage of the maintenance mode.
(2) Press the
0
,
6
,
2
, and
6
keys in this order.
The "HeadCalib->Media" appears on the LCD.
(3) Insert an external memory into the memory slot.
(4) Press the
SET
or
Mono Start
key.
The machine displays "Now Saving" on the LCD and starts the backup operation.
Upon completion of the backup operation, the machine beeps displays "Head
Calib.data" on the LCD and returns to the initial stage of the maintenance mode.
Restoration procedure
(1) Press the
6
and
8
keys in this order in the initial stage of the maintenance mode.
(2) Press the
0
,
6
,
2
, and
6
keys in this order.
The "HeadCalib->Media" appears on the LCD.
(3) Press the or key to display "Media->HeadCalib" on the LCD.
(4) Insert the external memory holding the head property data into the memory slot.
(5) Press the
SET
or
Mono Start
key.
The machine displays "Now Loading" on the LCD and starts the restoration
operation.
Upon completion of the restoration operation, the machine displays "Complete" on
the LCD and returns to the initial stage of the maintenance mode.
Note:
- If the external memory inserted in step (5) holds no head calibration data, the
"Can’t Open File" appears on the LCD.
- This procedure should be performed with the USB cable disconnected.
Summary of Contents for MFC-J6920DW
Page 123: ...3 3 Confidential 2 PACKING ...
Page 146: ...3 26 Confidential 3 Set the protective part Protective part ...
Page 308: ...5 37 Confidential pfadj2 Pattern ...
Page 315: ...5 44 Confidential Margin Check Pattern ...
Page 362: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...