![background image](http://html.mh-extra.com/html/brother/mfc-j6920dw/mfc-j6920dw_service-manual_17375345.webp)
5-74
Confidential
2.3
Retrieving the Equipment Log Information
< Function >
This procedure retrieves the log information from the machine to the connected PC as
electronic data.
< Operating Procedure >
(1) Turn ON your PC.
(2) Create an arbitrary folder in the C: directory and save the readback tool
(rb2k03.exe) and PJL command file (brmainten_77.pjl) in that folder.
Note:
The rb2k03.exe is available only in windows XP.
(3) Switch the machine to the maintenance mode. (Refer to
in this chapter.)
(4) Connect the machine to the PC using a USB cable.
(5) On the PC, start Command Prompt and change to the directory where the
readback tool is located.
(In the example below, a "SendPJL" folder is created in the C: directory and the
readback tool is saved in that folder.)
(6) In Command Prompt, type
rb2k03.exe brmainten_77.pjl brmainten_77.txt /T3
and press the
Enter
key.
Note:
Be sure to enter a space to the points marked with an asterisk (
*
) shown
below.
rb2k03.exe
*
brmainten_77.pjl
*
brmainten_77.txt
*
/T3
Otherwise, an error occurs.
brmainten_77.txt
is created in the arbitrary folder.
(7) In Excel, open the created header/footer and delete texts added by the PJL
stipulation.
Summary of Contents for MFC-J6920DW
Page 123: ...3 3 Confidential 2 PACKING ...
Page 146: ...3 26 Confidential 3 Set the protective part Protective part ...
Page 308: ...5 37 Confidential pfadj2 Pattern ...
Page 315: ...5 44 Confidential Margin Check Pattern ...
Page 362: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...