![background image](http://html.mh-extra.com/html/brother/mfc-j6920dw/mfc-j6920dw_service-manual_17375185.webp)
3-65
Confidential
Assembling Note:
Assemble a new Second side CIS flat cable by bending the
Second side CIS flat cable and affixing the Double-sided adhesive
tape as shown in the figure below.
Fig. 3-65
Harness routing:
Refer to
ADF unit and document scanner unit"
Supporting tape
Supporting tape
Tape
45°
34.04 mm
12.44±1
mm
66.9±1
mm
50.2±2
mm
153.87±1
mm
180.92±1
mm
785±8
mm
1.5±1 mm
(191.7 mm)
(126.2 mm)
49.67±1
mm
12±1.5
mm
Double-sided
adhesive tape
To main body
To CIS unit
Valley fold
Mountain fold