3-104
Confidential
9.50 Switchback Sensor PCB
(1) Release the six Hooks and remove the Tube support plate.
Fig. 3-121
(2) Release the wiring of the Switchback sensor harness.
(3) Release the two Hooks and remove the Switchback sensor PCB.
Fig. 3-122
Harness routing:
Main PCB ASSY and MJ PCB ASSY"
Hook
Hook
Hooks
Tube support plate
<Front>
<Rear>
1b
1a
Hook
Hook
Hooks
Switchback
sensor PCB
Switchback sensor PCB