install - concepts - PixMaster - switcher - CG - clips - controls - team - appendix
Broadcast Pix
V8.5
4.14.3 Fail-Safe Operation on Slate 5016G & 5032G
1.
The control panel will
automatically
detect the problem and the Fail-Safe device
will appear on the program monitor. At the same time the control panel will drop
into Fail-Safe mode, and the Display PixButtons will appear in ME 2, as shown
below. The Show Prev and Show Prog buttons will be on a shifted source on a
5032G.
2.
In Fail-Safe mode, all of the above buttons will still work. You can continue to
preview these sources on your external preview monitor and cut them to air with
the
[CUT]
button.
These source number refer to the router inputs. Inputs 1 through 12 are the
cameras and others external sources connected to inputs 1-12. On a Slate
5016G Sources 13-16 are the Slate workstation outputs for Program, Preview,
Aux Tie, etc. as assigned from the Slate IO Assignments window.
On a Slate 5032G, press
[Shift]
to access inputs 17-32. On a Slate 5032G
Sources 28-32 are the Slate workstation outputs for Program, Preview, Aux Tie,
etc. as assigned from the Slate IO Assignments window.
Keep in mind, when the control panel is in Fail-Safe mode, you have no access
to any internal content and your Multi-View is disabled.
To Return to Show Mode after the workstation recovers:
1.
Load a show
(if a show is not set to Auto-Load) by selecting
File, Load Show.
2.
Press the
[Join the Show]
PixButton in the upper right corner of Device Control-
A, to enter into the show and to return the control panel to its normal mode.
4.14.3
If during production the workstation should lock-up or the network connection should
fail:
0 1 2
4
Shift
3
1
1
1
1
1
1 2 3 4 5 6 7 8 9
Show
Prev
Show
Prog
CUT