3 608 878 300
Tightening Technology |
Bosch Rexroth AG 565
System 350
| 3 608 878 300/2019-03
The number of configured I/O modules at the communication partner (PLC) must correspond to the
setting in "Tightening channel configuration" / "KE configuration" in the BS350 because, otherwise, data
cannot be exchanged between the communication partner (PLC) and the tightening system.
No settings can be made in the
Configured ranges
field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
Index card: Configuration
The following settings can be made in this index card:
•
Get configuration via DHCP
or
•
Use the following configuration:
If you select this item, you can enter the following parameters:
–
IP address
: Assigned by the network administrator; identifies the participant in the data exchange
–
Subnet mask
: Assigned by the network administrator; contains information on the network
configuration (address range)
–
Gateway
: Establishes the external connection
•
Host name:
Name by which the Ethernet participant (here the KE of the tightening system) can be
addressed.
Index card: Station information
The station can be additionally assigned several attributes.
The
Station name
field is grayed out and cannot be changed.
The following entries can be made in this index card:
•
Additional information 1 - max 32 ASCII characters
•
Additional information 2 - max 22 ASCII characters
•
Additional information 3 - max 16 ASCII characters
•
Additional information 4 - max 54 ASCII characters
Create GSDML file button
If the IMpnio interface module is commissioned with the configuration program for PROFINET, this
configurator requires the participant profile in form of a GSDML (Generic Station Description Markup
Language - master data file) file. The GSDML file (
*.
gsd
) contains access points for the configuration of
the communication partner (PLC) and is generated independently from the parameters set in BS350 (e.g.
configured number of I points).
Click
Create GSDML file
to generate a GSDML file. Save the file and import it into the field bus
configurator.
The
Station name
has to be set by the master PLC using the
Naming
function.
To ensure communication of the
Rexroth Tightening System 350
with the communication partner via the
IMpnio interface module without errors, the station name at IMpnio and in the configuration program of
the IMpnio communication partner have to be identical.
The station name which the communication partner has assigned to the IMpnio can be checked under the
IMpnio "station information" (A-module) in "Tightening channel configuration" or "KE configuration".
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...