3 608 878 300
Tightening Technology |
Bosch Rexroth AG 535
System 350
| 3 608 878 300/2019-03
7.2.8.2
Modular system
LED displays
Tables
show the LED displays for the VM, SE, LT, and KE during the
starting/run-up phase
,
when they are
ready for operation
, and in
tightening operation
.
Starting/run-up
phase
Ready for operation
Tightening operation
NOTICE
Overvoltage
Control and power electronics can be damaged.
The BT voltage supply or the SB on/off switch (below the door) may only be switched on after all
modules have been fully inserted and secured with knurled bolts and all cables have been
connected and checked for proper fit.
Information on the operating states can be found in the project planning manual for the respective
component.
Table 7–7:
Starting/run-up phase
VM
SE
LT
KE
Green (static)
Red (static)
Green/red
flashing
Red (static)
Red (static)
Off
Red (static)
4
Table 7–8:
Ready for operation
VM
SE
LT
KE
Green (static)
Green (static):
Ready for
operation
Green (static):
Ready for
operation
Green (static):
Ready for
operation
Red (flashing):
error
Red (static): error
Red (static):
error
Green/red
flashing:
logon to CAN bus
Red (flashing):
no
tightening took
place
beforehand.
Off
Off
4
Table 7–9:
Tightening operation
VM
SE
LT
KE
Green (static)
Green (static):
Ready for
operation
Green (static):
Ready for
operation
Green (static)
Red (flashing):
error
Red (static):
error
Green (flashing):
emergency
STOP chain
interrupted
1
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...