482
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
Configuration of the PLC interfaces
The KE IL signals 128.0-129.7 are assigned to the PNIO address range 0-1. Any applied tightening
system signals replace the KE IL signals and the bit addresses for PNIO and KE IL remain consistent
(128).
The signals have to be applied to the internal IL range as follows:
Example
Input signals:
– FC En to A 0.0
– FC ResF to A 0.1
– KE ResF to A 0.2
– KE ILIn 128.3 to A 0.3
– KE ILIn 128.4 to A 0.4
– KE ILIn 128.5 to A 0.5
– KE ILIn 128.6 to A 0.6
– KE ILIn 128.7 to A 0.7
– KE ILIn 129.0 to A 1.0
– KE ILIn 129.1 to A 1.1
– KE ILIn 129.2 to A 1.2
– KE ILIn 129.3 to A 1.3
– KE ILIn 129.4 to A 1.4
– KE ILIn 129.5 to A 1.5
– KE ILIn 129.6 to A 1.6
– KE ILIn 129.7 to A 1.7
Example
Output signals:
– KE Rdy to A 0.0
– FC NF to A 0.1
– KE NF to A 0.2
– FC Rdy to A 0.3
– FC BypsAc to A 0.4
– KE ILOut 128.5 to A 0.5
– KE ILOut 128.6 to A 0.6
– KE ILOut 128.7 to A 0.7
– KE ILOut 129.0 to A 1.0
– KE ILOut 129.1 to A 1.1
– KE ILOut 129.2 to A 1.2
– KE ILOut 129.3 to A 1.3
– KE ILOut 129.4 to A 1.4
– KE ILOut 129.5 to A 1.5
– KE ILOut 129.6 to A 1.6
– KE ILOut 129.7 to A 1.7
– KE Rdy to IL 8.0
– Ch 0.5 NF to IL 10.4
– Ch 3.3 NF to IL 12.4
– FC NF to IL 8.1
– Ch 0.6 NF to IL 10.5
– Ch 3.4 NF to IL 12.5
– KE NF to IL 8.2
– Ch 1.1 NF to IL 10.6
– Ch 3.5 NF to IL 12.6
– FC Rdy to IL 8.3
– Ch 1.2 NF to IL 10.7
– Ch 3.6 NF to IL 12.7
– FO 1 InCy to IL 9.0
– Ch 1.3 NF to IL 11.0
– Ch 4.1 NF to IL 13.0
– FO 2 InCy to IL 9.1
– Ch 1.4 NF to IL 11.1
– Ch 4.2 NF to IL 13.1
– FO 3 InCy to IL 9.2
– Ch 1.5 NF to IL 11.2
– Ch 4.3 NF to IL 13.2
– FO 4 InCy to IL 9.3
– Ch 1.6 NF to IL 11.3
– Ch 4.4 NF to IL 13.3
– FO 5 InCy to IL 9.4
– Ch 2.1 NF to IL 11.4
– Ch 4.5 NF to IL 13.4
– FO 6 InCy to IL 9.5
– Ch 2.2 NF to IL 11.5
– Ch 4.6 NF to IL 13.5
– FO 7 InCy to IL 9.6
– Ch 2.3 NF to IL 11.6
– Ch 5.1 NF to IL 13.6
– FO 8 InCy to IL 9.7
– Ch 2.4 NF to IL 11.7
– Ch 5.2 NF to IL 13.7
– Ch 0.1 NF to IL 10.0
– Ch 2.5 NF to IL 12.0
– Ch 5.3 NF to IL 14.0
– Ch 0.2 NF to IL 10.1
– Ch 2.6 NF to IL 12.1
– Ch 5.4 NF to IL 14.1
– Ch 0.3 NF to IL 10.2
– Ch 3.1 NF to IL 12.2
– Ch 5.5 NF to IL 14.2
– Ch 0.4 NF to IL 10.3
– Ch 3.2 NF to IL 12.3
– Ch 5.6 NF to IL 14.3
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...