160
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
NokAc
E
Not OK Acknowledge
Restart after NOK tightening is prevented.
Ok
A
OK
This signal indicates that the tightening
application or KE tightening process was
evaluated with OK.
Prog0-7
E
Program 0-7
Binary coded program number to tightening
controller.
RC0-4
A
Rework Code Bit 0-4
Binary coded rework code.
Rdy
A
Ready
Tightening application can only be started once
this signal is set to "high".
RedH
A
Redundancy too high
The redundancy is above the defined tolerance
window.
ResRs
E
Reset Result
PLC signals of monitoring functions and
CyCmp OK and SO x NOK are set.
CyCmp OK and monitoring signals like TorqH
are reset and NOK is set.
SEn
E
Signal Enable
Enable channel x.y signals.
SEnAc
A
Signal Enable Acknowledge
Acknowledge enable the signals
of channel x.y
StartBn
A
Start switch
Status of the start switch on the ErgoSpin.
StickSlipH
A
Stick Slip Too High
The number of stick slips is above the defined
tolerance window.
TimeH
A
Time too high
The time is above the defined tolerance window.
ToolBn
A
Tool button
Status of the tool button on the ErgoSpin.
TorqAvrH
A
Torque average too high
The average torque value is above the defined
tolerance window.
TorqAvrL
A
Torque average too low
The torque average value is below the defined
tolerance window.
TorqCtrH
A
Torque control too high
The maximum torque control is above the
defined limit.
TorqCtrL
A
Torque control too low
The tightening torque is below the defined limit.
TorqH
A
Torque too high
The torque is above the defined tolerance
window.
TorqL
A
Torque too low
The torque is below the defined tolerance
window.
TorqMaxH
A
Torque max too high
The maximum torque is above the defined
tolerance window.
TorqMinL
A
Torque min too low
The minimum torque is below the defined
tolerance window.
TorqRelH
A
Torque relative too high
The relative torque is below the defined
tolerance window.
TorqRelL
A
Torque relative too low
The relative torque is below the defined
tolerance window.
TorqRgeH
A
Torque range too high
The torque range is above the defined tolerance
window.
TorqRgeL
A
Torque range too low
The torque range is below the defined tolerance
window.
TrigOut
A
Trigger Out
Trigger output is set as soon as the set
condition has been reached.
UsrIn1
E
User Input 1
External input signal with program functions.
UsrIn2
E
User Input 2
External input signal with program functions.
YieldH
A
Yield too high
The yield point was reached.
1
CH x.y (fastening channel) tightening channel
2
As of version V2.600 of the Rexroth Tightening System 350, this signal is replaced by the MntTool signal.
Signals
1
CH x.y
E/A
Function channel x.y ...
Description
The KE control interface can be used to access single-channel signals. The extension Ch x.y is preset in
addition to the single-channel signal, e.g. Ch 1.2 CyCmp.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...