3 608 878 300
Tightening Technology |
Bosch Rexroth AG 145
System 350
| 3 608 878 300/2019-03
Setting: Transfer before the end of the tightening program or the tightening application(
CyCmp
):
If transfer via Ethernet is not possible, the tightening program or tightening sequence is stopped
immediately. The
FtpF
error signal is "high" (FTP error) and signal
KE NF
="low" (
KE No Fault
) is
generated, with the corresponding entry being made in the error list.
GradAvrH
Gradient average too high: Gradient average value too high
Output signal used for:
•
Tightening channel (
GradAvrH
)
•
Communication unit in single-channel operation (
CH x.y GradAvrH
)
Results description after a completed tightening sequence. The gradient average value exceeds the
defined tolerance window.
GradAvrL
Gradient average too low: Gradient average value too low
Output signal used for:
•
Tightening channel (
GradAvrL
)
•
Communication unit in single-channel operation (
CH x.y GradAvrL
)
Results description after a completed tightening sequence. The gradient average value is below the
defined tolerance window.
GradH
Gradient too high: Gradient too high
Output signal used for:
•
Tightening channel (
GradH
)
•
Communication unit in single-channel operation (
CH x.y GradH
)
Results description after a completed tightening sequence. The gradient is above the defined tolerance
window.
GradL
Gradient too low: Gradient too low
Output signal used for:
•
Tightening channel (
GradL
)
•
Communication unit in single-channel operation (
CH x.y GradL
)
Results description after a completed tightening sequence. The gradient is below the defined tolerance
window.
GO_Rdy
Geared offset head ready: Flat output drive referenced
This signal is available as of version V2.400 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel (
GO_Rdy
)
•
Communication unit in single-channel operation (
CH x.y GO_Rdy
)
This signal reports referencing of the open position of the flat output drive. If the
GO_Rdy
is "high",
referencing is completed. If the value is set to "low", the flat output drive was not referenced after restart,
the ErgoSpin hand-held nutrunner was disconnected or referencing is not completed.
For using the signal, the option
Open flat key program-controlled
has to be activated in the
configuration of the flat output drive
. Otherwise, the error message 1213 is issued.
GO_Open
Geared offset head open: Flat output drive open
This signal is available as of version V2.400 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel (
GO_Open
)
•
Communication unit in single-channel operation (
CH x.y GO_Open
)
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...