System 350
| 3 608 878 300/2019-03
IMecat
IMecat is supported as of version V2.500 of the
Rexroth Tightening System 350
:
This parameter dialog consists of two index cards that can be selected in the
Set up EtherCat interface
group:
•
I/O and data
•
Device information
Index card: I/O and data
No settings can be made in the
Configured ranges
field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
Index card: Device information
In this index card, the Device ID is set.
Create description file button
A participant profile in form of a description file (
*.xml
) is required to commission the IMecat interface
module. The description file enables the software to recognize the variable parameters and their value
ranges.
Click
Create description file
to generate a description file. Save the file and import it into the field
bus configurator.
Click
Accept
to transfer the data to the configuration for the tightening channel in the BS350.
Type B interface modules (B1 and B2)
This interface is intended for the use of type B interface modules from Rexroth.
•
IM24V for reading 24 V I/O signals in and out (e. g. for actuating lamps and buttons)
Open the associated parameter dialog by double clicking the parameter field in line B1 or B2 (see Figure
In the
Select interface module
), select the desired module from the drop-
down list and set its parameters.
Table 7–23:
Settings in BS350 for IMcat - I/O and data
Element
Description
Number of I points
Number of control signals to be processed via the EtherCat interface. Value range
16 to 64 input signals (2 to 8 bytes)
Number of O points
Number of control signals to be processed via the EtherCat interface. Value range
16 to 64 output signals (2 to 8 bytes)
Receive data
Memory location for receiving the ID code, max. 64 bytes
Send data
Memory location for sending results, max. 252 bytes at 2 bytes for O points
Receive IL data
Memory location for receiving IL data, max. 252 bytes at 2 bytes for I points
These data are processed using the IL function block ControlFieldbus.
Send IL data
Memory location for sending of IL data, max. 252 bytes at 2 bytes for O points
These data are processed using the IL function block ControlFieldbus.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...