Element name
Data type
Direction
Parameter in MLD master Parameter in axis
Significance
Axis_Error
BIT
Act. value
P-0-166x.13
S-0-0135 (bit13=1)
Drive error, error in
class 1 diagnostics
Axis status (PLCopen state machine)
Errorstop
BIT
Act. value
-
-
PLCopen status: Error‐
stop
Stopping
BIT
Act. value
-
-
PLCopen status: Stopping
Homing
BIT
Act. value
-
-
PLCopen status: Homing
DiscreteMotion
BIT
Act. value
-
-
PLCopen status: Discre‐
teMotion
ContinuousMotion
BIT
Act. value
-
-
PLCopen status: Continu‐
ousMotion
SynchronizedMotion
BIT
Act. value
-
-
PLCopen status: Syn‐
chronizedMotion
StandStill
BIT
Act. value
-
-
PLCopen Status: Stand‐
Still
Disabled
BIT
Act. value
-
-
PLCopen status: Disabled
PreSetMode
BIT
Act. value
-
-
PLCopen status: PreSet‐
Mode
Element name
IEC name of the data element. This is the name
used to address the structure element in the pro‐
gram
Data type
IEC data type of the data element
Direction
Command values are written by the user and
transmitted by the system
Parameter in MLD master The master contains a diagnostic parameter for
this element. This parameter displays the value
but is not writable
Parameter in axis
Source or target parameter on the respective axis.
A fixed parameter can be contained here. The pa‐
rameter can be set for the configurable elements.
For the other elements, there is no parameter on
the axis.
Tab. 5-2:
Structure of AxisData
Configurable contents
The following elements can be assigned to different axis parameters by con‐
figuring them accordingly. The AxisData dialog is used for configuration (see
also "
●
Configurable command value bits
It is possible to command up to four freely configurable parameter bits
for each real axis with the elements "wUserCmdDataBitA_q" to "wU‐
serCmdDataBitD_q".
●
Configurable command values
It is possible to command up to four freely configurable parameter bits
for each real axis with the elements "dwUserCmdDataA_q" to "dwU‐
serCmdDataD_q".
●
Configurable actual value bits
It is possible to read in up to four freely configurable parameter bits from
each real axis with the elements "wUserActualDataBitA_i" to "wUserAc‐
tualDataBitD_i".
●
Configurable actual values