Fig. 8-6:
Example of storage location and name of a version function
Library name
Syntax type
Prefix
Suffix
Name of library function
Base_12
A
Version_
V02
Version_MS_Base_12V02
Tab. 8-6:
Examples of library function names
Message during download
When a firmware library is included in a user project, all functions/function
blocks contained in the firmware library are linked during the download. (POE
linking and version protection might possibly not have been implemented on
all targets).
If one or more functions cannot be linked, the download is aborted with an
error message.
Fig. 8-7:
Message of a failed version check
The error message contains a list indicating which functions/function blocks
from which library could not be linked. A reference list (e.g., from the Firm‐
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
233/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Programming information
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01