Fig. 7-18:
Making the Archive Target Settings
●
Filing on file system
If you would like to store the archive on the file system, tick the
Store archive on file system check box; the Target directory edit
field then can be written. Define the directory of the file system in
which the archive is to be stored.
●
Filing on FTP server
If you would like to store the archive on an FTP server, tick the
Store archive on FTP server (device or computer) check box; the
Device name, host name or IP address edit field then can be writ‐
ten. Define the target device on which the archive is to be stored.
There are four options to do this:
1. IP address
OR
2. Host name of the target device
OR
3. Selection via the selection list. It contains all FTP-compatible
devices of the active project and the last five target devices
used for archiving (device name, IP address or host name).
OR
4. With the ... button, the target device can be selected from a
list of all FTP-compatible devices of the active project.
6. Click Next>>.
⇒ A connection to the device that has been set is automatically estab‐
lished. Disruptions in the connection to the target device are displayed
by means of an error message.
7. In the following dialog, the archive components must be selected:
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
194/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Notes on commissioning and application
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01