Fig. 7-13:
Saving projects in the drive
The "program download" only loads the PLC program to the RAM of the
drive. When the boot project is transmitted to the drive with the Load boot
project menu item, IndraLogic first transmits several files that, by default, are
stored in the drive in coded and compressed form as a set of several param‐
eters.
●
Operation without external memory card
If an external memory card is not available, the source code is stored in
parameters.
●
External memory card as active memory
If an external memory card is available, the PLC project as source code
and the symbol configuration can be additionally stored in the drive. In
this case, the boot project and the symbol configuration are contained in
the parameter file on the external memory card.
Boot project
The boot project can be loaded and saved with IndraWorks MLD as parame‐
ters (P-0-1352 to P-0-1358). This means a backup of the parameters con‐
tains the boot project, i.e., the binary code, but not the source code.
The boot project of the PLC has the following properties:
●
It consists of several system files. They contain the binary project with‐
out symbolic information. With Create boot project (online only), the sys‐
tem files are automatically loaded to the drive.