Element name
Data type
Direction
Parameter in MLD master Parameter in axis
Significance
dwUserActualDataD_i
SM_TYPES Act. value
32-bit source parameter:
P-0-180x
16-bit source parameter:
P-0-189x
(configurable)
Actual value for free use
Axis status information (normally accessed via status bits or axis status [PLCopen state machine])
wDriveStatus_i
WORD
Act. value
P-0-166x
S-0-0135
Axis status - the bits are
individually available
wDriveExtStatus_i
WORD
Act. value
-
-
Axis status - the bits are
individually available
wSignalStatus_i
WORD
Act. value
P-0-171x
S-0-0144
Signal status - the bits are
individually available
wSyncStatus_i
WORD
Act. value
P-0-181x
P-0-0089
Synch status - the bits are
individually available
dwDeviceStatus_i
DWORD
Act. value
P-0-1630.x.2
S-0-1045
Device status - the bits
are individually available
dwPLCopenStatus_i
DWORD
Act. value
-
-
PLCopen-based status -
the bits are individually
available
dwDiagNumber_i
DWORD
Act. value
P-0-170x
S-0-0390
Diagnostic message num‐
ber
Fixed actual values
rActualPosition_i
REAL
Act. value
P-0-167x
S-0-0386
Active actual position val‐
ue
rActualVelocity_i
REAL
Act. value
P-0-168x
S-0-0040
Velocity feedback value
rActualTorqueForce_i
REAL
Act. value
P-0-169x
S-0-0084
Torque/force feedback
value
Fixed state bits
Axis_CamTab_0
BIT
Act. value
P-0-181x.0
P-0-0089.0
Active cam shaft bit#0
Axis_CamTab_1
BIT
Act. value
P-0-181x.1
P-0-0089.1
Active cam shaft bit#1
Axis_CamTab_2
BIT
Act. value
P-0-181x.2
P-0-0089.2
Active cam shaft bit#2
Axis_CamSwitching
BIT
Act. value
P-0-181x.5
P-0-0089.5
Status distance switching
Axis_CmdValueReached
BIT
Act. value
P-0-171x.0
P-0-0115.12
Command value reached
Axis_Standstill
BIT
Act. value
P-0-171x.1
S-0-0331.0
Standstill message
Axis_InSynchron
BIT
Act. value
P-0-181x.8
P-0-0089.8
Slave axis has been
synchronized
Axis_Homed
BIT
Act. value
P-0-171x.2
S-0-0403.0
Status of actual position
value reference encoder
Axis_Inbb
BIT
Act. value
P-0-166x, bit (!15 & 14)
S-0-0135 (bit 15 | bit 14 )
Control section ready for
operation
Axis_InAb
BIT
Act. value
P-0-166x, bit (15 & !14)
S-0-0135 (bit15=1)
Control and power sec‐
tions ready for operation
Axis_Power
BIT
Act. value
P-0-166x, bit (15 & 14)
S-0-0135 (bit15=1 &
bit14=1)
Drive with torque
Axis_FollowingCommand BIT
Act. value
P-0-166x, bit 3=1
S-0-0135 (bit 3=1)
Drive follows command
value input by MLD
Axis_Interrupted
BIT
Act. value
P-0-166x (bit15=1 &
bit14=1 & bit13=0 &
bit3=0) and
P-0-165x (bit13=1)
S-0-0135 (bit15=1 &
bit14=1 & bit13=0 &
bit3=0) and
S-0-0134 (bit13=1)
Motion commanding was
interrupted by higher-level
drive function
Axis_Warning
BIT
Act. value
P-0-166x.12
S-0-0135.12
Class 2 diagnostics
change bit - warning
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
94/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
MLD communication interfaces and data channels
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01