Figure name DB000194
Fig. 6-8:
Advanced connection settings for communication with a drive
controller (and its MLD) (Ethernet)
10. Enter IP address of drive (e.g., 192.168.0.32).
The IP address(es) of the drive is/are displayed in parameters
P-0-1531, P-0-1641 and S-0-1020 or can be read at the control
panel of the drive.
Exception: Ethernet network - one VCP for multiple IndraDrive controllers
Communication via Ethernet enables the user to visualize or edit the data of
several drives via an operator terminal. When multiple drives are connected
to a VCP via Ethernet, this is called an "Ethernet network".
Fig. 6-9:
Ethernet Network via the MultiEthernet interface of IndraDrive Cs
Requirements for an "Ethernet
network"
An Ethernet network between the drives can only be established via the
MultiEthernet interfaces of the connected drive controllers in combination with
a hub/switch.
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
145/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Visualization and engineering interfaces