Description
Symbol
Unit
HCS01.1E
-W0005-
_-03
HCS01.1E
-W0008-
_-03
HCS01.1E
-W0018-
_-03
HCS01.1E
-W0028-
_-03
HCS01.1E
-W0054-
_-03
Power factor of fundamental com‐
ponent DPF at P
DC_cont
(single-
phase, with mains choke)
cosφ
h1
-
Power factor of fundamental com‐
ponent DPF at P
DC_cont
(three-
phase, with mains choke)
cosφ
h1
-
tbd
0.99
0.95
Last modification: 2012-06-28
1) 2)
Mains voltage > U
LN
: Use a transformer with
grounded neutral point, do not use autotransform‐
ers!
3)
Otherwise use HNL mains choke
4)
Maximum allowed number of switch-on processes:
250000
5) 6) 7) 8) 10) 11) 12) 13) Find interim values by interpolation
9)
Copper wire; PVC-insulation (conductor tempera‐
ture 90 °C; T
a
≤ 40 °C) in accordance with
NFPA 79 chapter 12 and UL 508A chapter 28
Tab. 7-43:
HCS - Mains voltage supply data
I
L_trans_max_on
Maximum inrush current
U
LN
Mains voltage
Fig. 7-37:
Maximum inrush current vs. Mains voltage
DOK-INDRV*-HCS01******-PR05-EN-P
Bosch Rexroth AG
239/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components