IEC / EN
61800-3
CISPR 11
(EN55011)
Explanation
Curves of
limit value
character‐
istic
Category C3,
2nd environ‐
ment
Class A; Group
2
I < 100 A
Limit value in industrial areas to be complied with for applications operat‐
ed at supply mains with nominal currents < 100 A.
2.1
2.2
Category C2,
1st environ‐
ment;
Restricted dis‐
tribution
Class A;
Group 1
Limit value in residential area or at facilities at low-voltage mains supply‐
ing buildings in residential areas. To be complied with for applications with
restricted distribution.
3.1
3.2
Category C1,
1st environ‐
ment;
Unrestricted
distribution
Class B;
Group 1
Limit value in residential areas to be complied with for applications with
unrestricted distribution.
4.1
4.2
Tab. 4-40:
Limit Value Classes