Resolver without encoder data memory
See the connection diagram for how to connect the encoder system.
Connection diagram
1)
Line cross section ≥ 0.5 mm²; observe allowed encoder cable
length
2)
Line cross section ≥ 0.14 mm²
Fig. 7-12:
EC connection diagram with resolver encoder system
Power supply
The EC interface supplies the resolver encoder system with a carrier voltage
amplitude of 11 V
pp
.
Technical specification of the power supply: See
Please observe that the resolver encoder used has to be suited
for the voltage available at the EC interface as the encoder supply
voltage.
Cable length
75 m at most
Specific technical features
The encoder evaluation has been sized for resolvers with a transfer ratio of
0.5.
Resolvers are not supported if an optional "Safe Motion" safety technology is
available at the same time.
DOK-INDRV*-HCS01******-PR05-EN-P
Bosch Rexroth AG
193/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components