Description
Symbol
Unit
HCS01.1E
-W0003-
_-02
HCS01.1E
-W0006-
_-02
HCS01.1E
-W0009-
_-02
HCS01.1E
-W0013-
_-02
HCS01.1E
-W0018-
_-02
Three-phase mains voltage at IT
mains
1)
U
LN
V
110...230
Three-phase mains voltage at
Corner-grounded-Delta mains
2)
U
LN
V
110...230
Tolerance rated input voltage U
LN
%
± 10
Minimum short circuit power of the
mains for failure-free operation
S
k_min
MVA
0.02
0.03
0.05
0.1
0.2
Minimum inductance of mains
supply (mains phase inductance)
3)
L
min
µH
40
Assigned type of mains choke
-
Inrush current
I
L_trans_max
_on
A
See figure
Maximum allowed ON-OFF cycles
per minute
4)
1
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(single-
phase, without mains choke)
5)
I
LN
A
1.80
2.80
5.00
8.30
12.80
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(three-phase,
without mains choke)
6)
I
LN
A
0.60
1.20
2.30
4.50
9.60
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(single-
phase, with mains choke)
7)
I
LN
A
-
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(three-phase,
with mains choke)
8)
I
LN
A
-
Nominal current AC1 for mains
contactor at nom. data
ILN
Mains
fuse
according
to
EN 60204-1 (single-phase, with‐
out mains choke)
A
4;gG
6;gG
10;gG
16;gG
Mains
fuse
according
to
EN 60204-1 (three-phase, without
mains choke)
A
2;gG
4;gG
6;gG
16;gG
Mains
fuse
according
to
EN 60204-1 (single-phase, with
mains choke)
A
-
Mains
fuse
according
to
EN 60204-1 (three-phase, with
mains choke)
A
-
Last modification: 2012-06-28
Bosch Rexroth AG
DOK-INDRV*-HCS01******-PR05-EN-P
234/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components