AutoDome 600 Series Analog PTZ Camera
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en
33
Bosch Security Systems, Inc.
Installation Manual
F.01U.215.782 | 1.0 | 2011.04
10. If using a coax cable, connect the incoming coax cable to the BNC jack (female connector
enclosed by the plastic cover) on the coax cable with ferrite. Slide the plastic cover over
the connection. Refer to
Section 2.4.1 Coaxial Cable Connections, page 17
.
11. Connect the BNC plug (male connector) of the coax cable with ferrite to the BNC jack
connector from the Pendant Connector Harness and slide its plastic cover over the
connection.
Section 2.4.1 Coaxial Cable Connections, page 17
.
12. If using UTP for video, connect the incoming RJ45 video connector, installed previously,
to the UTP Video/Ethernet cable (cable 5). Refer to
Section 5 Cable and Wire Standards,
page 70
, for detailed wire and connection information.
13. Connect the outgoing alarm wires to the flying leads coming from the 4-pin Alarm
Outputs cable (cable 6).
14. Connect the incoming alarms wires to the flying leads coming from the 6-pin Alarm Inputs
cable (cable 7).
15. Connect the incoming serial communication wires to the 6-pin mating connector supplied
with the VG4-A-ARMPLATE kit. Ensure that the 100 Ω resistor remains connected to the
Biphase C- and the Biphase C+ terminals. Remove the resistor only in the following cases:
–
If the AutoDome is not the last AutoDome in a daisy chain.
–
If the Biphase C- and the Biphase C+ terminals receive a line input audio signal.
Refer to
Section 5 Cable and Wire Standards, page 70
, for detailed wire and connection
information.
16. Attach the 6-pin serial communication mating connector to the Serial Communication
(cable 8) cable.
17. Connect the Earth ground wire, if available, to the crimp ring terminal inside the
Mounting Plate. Refer to
Figure 2.15
above.
Note
: The Earth ground is not provided with the VG4-A-ARMPLATE kit; it is a ground
connection made at the installed location.
18. After making the harness connections to the Mounting Plate, rotate the Pendant Arm to
close and tighten the two (2) captive screws to 10-12 N-m (90-105 in.-lbs).
2.9
Prepare Pendant for Installation
The inside of the pendant housing contains packing material to safeguard the camera during
shipping. You must remove the packing material before attaching the pendant to the mount,
by removing the bubble.
1.
Open the top of the box containing the pendant housing, and remove the top foam insert.
2.
Remove the pendant housing from the box and from the plastic bag and place the
pendant housing back into the packing box, bubble facing up.
Reserve all packing material in case you must return the unit.
3.
Using both hands, apply a clockwise (looking down at the dome) rotational force on the
Pendant Bubble Assembly to set the bubble latch.
4.
Insert a small (2 mm) straight blade screw driver into the bubble release opening in the
bubble trim-ring to release the lock, and then remove the screwdriver. See the figure
below.
NOTICE!
After all wiring is complete, close the cover door and tighten the two (2) captive
screws on the cover door to 10-12 N-m (90-105 in.-lbs).