AutoDome 600 Series Analog PTZ Camera
Installing Roof Parapet and Pipe Mounts | en
47
Bosch Security Systems, Inc.
Installation Manual
F.01U.215.782 | 1.0 | 2011.04
The following table lists the Power Supply Box connectors:
Table 3.1
Power Box Connections
3.5
Installing the VG4-A-9230 Roof Parapet Mount
This section details the installation steps for the Roof Parapet Mount. If you are installing a
pipe mount, refer to
Section 3.6 Installing the VG4-A-9543 Pipe Mount, page 50
, for
instructions.
Figure 3.6
VGA-A-9230 Parapet Roof Mount
1.
Determine the wall location on the roof for the AutoDome and use the Parapet wall
mount bracket as a template to mark the hole locations.
No.
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Ground
Grounding Screw
P101
115/230 VAC or 24
VAC Power In
Line
NC
Neutral
P105
Control to Dome
(Fiber Optic
Model)
C-
(Biphase)
C+
(Biphase)
Earth
Ground
RXD (+)
(RS-232/485)
TXD (-)
(RS-232/485)
Signal
Ground
P106
Control In/Out
(Optional)
C-
(Biphase)
C+
(Biphase)
Earth
Ground
RXD (+)
(RS-232/485)
TXD (-)
(RS-232/485)
Signal
Ground
P107
24 VAC Power to
Dome Plug
Dome
24 VAC
Dome
24 VAC
Earth
Ground
Heater
(24 VAC)
Heater
(24 VAC)
NOTICE!
Allow enough room below the Parapet Mount Bracket to route the video, control and
alarm wires up through the Parapet arm. In certain installations you may have to lift the
Parapet arm for the AutoDome to clear the top of the wall when it is swung into position.
Provide enough slack in the wires to rotate the pipe arm over the roof and back when camera
maintenance is required.