3.
From the AutoDome main menu, select Alarms Setup>Inputs Setup, and set the Alarm
Input # to N.O.S. See the table below for contact and condition details.
6.2.2
Configuring a Normally Closed Supervised Alarm
1.
Install a 2.2 K end-of-line resistor in the alarm circuit.
2.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
AutoDome.
Figure 6.2
N.C.S. - Normally Closed Supervised Connections
3.
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.C.S. See the table below for contact and condition details.
AutoDome Programmed N.O.S.
Contact
Alarm Condition
Open
Normal
Closed
Alarm
Cut or brake
Tamper
1
Dry Contact
3
Dome Connector
2
Alarm 1 or 2 only (Pin 5 or 6)
4
Ground (Pin 7)
AutoDome Programmed N.C.S.
Contact
Alarm Condition
Open
Alarm
Closed
Normal
Short
Tamper
2.2K