AutoDome 600 Series Analog PTZ Camera
Installing the In-Ceiling Mount | en
59
Bosch Security Systems, Inc.
Installation Manual
F.01U.215.782 | 1.0 | 2011.04
4.2
Pre-installation Check List
1.
Determine the location and distance for the power supply box based on its voltage and
current consumption. Refer to
Section 5 Cable and Wire Standards, page 70
for
specifications.
2.
Install all rough wiring including: power, control, video, alarms I/O, relay I/O, and fiber
optic cabling.
3.
If you plan to use the RS232 or RS485 protocol to control the AutoDome, refer to
Section 5.4.2 Controlling the AutoDome via the RS232 Protocol, page 74
, or
Section 5.4.3 Controlling the AutoDome via the RS485 Protocol, page 75
, for instructions on
configuring the AutoDome to accept these protocols.
4.
A minimum of 216-mm (8 1/2-inch) of air space above the ceiling is required to install the
In-ceiling Mount.
5.
If this AutoDome installation utilizes the AutoTracker feature, refer to
Section A Installation Notes for AutoTracker, page 85
, before mounting the AutoDome.
4.3
Dimensions
Figure 4.1
In-ceiling Dimensional Outline
WARNING!
24 VAC Class 2 power supply only.
mm
inches
210.7
8.30
19.0
0.75
153.9
6.06
150.2
5.91
94.0
3.70
176.8
6.96
204.3
8.04
DIA.