en | Cable and Wire Standards
AutoDome 600 Series Analog PTZ Camera
F.01U.215.782 | 1.0 | 2011.04
Installation Manual
Bosch Security Systems, Inc.
5.4.2
Controlling the AutoDome via the RS232 Protocol
(3-wire, full-duplex, single-ended, 50 ft. cable limit)
RS232 is a common, single-ended communication protocol used for control. Data
transmission via 3-wires (TDX, RXD, common) is from one transmitter to one receiver at
relatively slow baud rates (up to 57.6 Kbaud) and short distances up to 50 ft.
Figure 5.4
Connections for RS232 Operation
NOTICE!
After making the wire connections for RS232 operation, reposition the slide switch located on
the CPU Module to the camera head inward and away from the LEDs.
Wire Type
3-wire (TXD, RXD, common)
Distance
15 m (50 ft)
Maximum Baud Rate
57.6 Kb
Voltage
± 15 V
Termination
100 Ω
Slide Switch
Away from LEDs (factory default)
1
C- (Biphase)
7
AutoDome Data In/Out
2
C+ (Biphase)
8
P105/P106 Connector
3
Earth Ground
9
Head End RS232
4
RxD
10
TxD
5
TxD
11
RxD
6
Signal Ground
12
Ground