64
en | Installing the In-Ceiling Mount
AutoDome 600 Series Analog PTZ Camera
F.01U.215.782 | 1.0 | 2011.04
Installation Manual
Bosch Security Systems, Inc.
10. To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying leads to the appropriate alarm wires. Then
connect the plugs to their mating connectors P103 and P102 in the Interface Box.
Figure 4.8
Alarm and Relay Connector Plugs
11. To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board. Refer to
Section 6 Alarms and Relay
Connections, page 79
for more details on wiring alarms.
12. Attach the lid to the Interface box:
a.
Align the slots on the lid with the two posts at the rear of the Interface box.
b.
Rotate the lid down.
c.
Squeeze the ground clips, located at the front of the box, against the Interface box
with your fingers before closing the lid to ensure that the lid does not catch on the
ground clips.
d.
Secure the lid to the Interface box by pushing the lid down until the clip on the lid
catches against the box.
1
4-pin Alarm Connector
(P102)
2
*
6-pin Alarm In Connector
(P103)
3
7-pin Relay Connector
(P104)
Pin Description
Pin Description
Pin Description
1
Alarm Out 1
1
Alarm In 3
1
Normally Open
2
Alarm Out 2
2
Alarm In 4
2
COM
3
Alarm Out 3
3
Alarm In 5
3
Normally Closed
4
Alarm Ground
4
Alarm In 6
4
Earth Ground
5
Alarm In 7
5
Analog Alarm 1
6
Alarm Ground
6
Analog Alarm 2
* Low Voltage TTL (3.3V) can also be used.
7
Ground
1
1
2
3
4
5
6
2
3
4
N
.O. COM
N
.C.
A1 GND
A2
1
PIN
PIN
P102
P103
P104
WHITE
ORANGE
BROWN
GREEN
WHITE
ORANGE
BROWN
GREEN
YELLOW
BLUE
2
3
4
5
6
7