AutoDome 600 Series Analog PTZ Camera
Alarms and Relay Connections | en
81
Bosch Security Systems, Inc.
Installation Manual
F.01U.215.782 | 1.0 | 2011.04
6.3
Configuring Non-supervised Alarms (inputs 1 through 7)
You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
6.3.1
Configuring a Normally Open Non-supervised Alarm
1.
Connect the alarm to the appropriate input (1 through 7) and ground at the AutoDome.
Figure 6.3
N.O. - Normally Open Non-supervised Connections
2.
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.O. See the table below for contact and condition details.
6.3.2
Configuring a Normally Closed Non-supervised Alarm
1.
Connect the alarm to the appropriate input (1 through 7) and ground at the AutoDome.
Figure 6.4
N.C. Normally Closed Non-supervised Connections
2.
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.C. See the table below for contact and condition details.
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 1 to 7
4
Ground
AutoDome Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 1 to 7
4
Ground
AutoDome Programmed N.C.
Circuit
Alarm Indication
Open
Alarm
Closed
Normal
Summary of Contents for AutoDome 600 Series
Page 1: ...AutoDome 600 Series Analog PTZ Camera AutoDome 600 Series en Installation Manual ...
Page 2: ......
Page 90: ......
Page 91: ......