62
en | Installing the In-Ceiling Mount
AutoDome 600 Series Analog PTZ Camera
F.01U.215.782 | 1.0 | 2011.04
Installation Manual
Bosch Security Systems, Inc.
4.6.1
Coaxial Cable Connections
If you are using coaxial cable to connect an AutoDome to a head-end system, you must use the
coaxial cable with ferrite included in the AutoDome packaging. The following illustration
shows the components of this cable:
Figure 4.6
Coaxial cable with ferrite
You must connect the incoming coax cable (from the head-end) to the BNC jack (item 4
above) on the ferrite cable and connect the BNC plug (item 1) of the ferrite cable to the BNC
jack connector inside the Interface box.
The following illustration shows coaxial cable with ferrite inside the Interface Box.
Figure 4.7
Interface Box Connection with Coaxial Cable with Ferrite
4.6.2
Make the Connections
After routing all video, control, power, and alarm wires:
1.
Attach a 3/4-inch NPS (20-mm) conduit fitting to the hole in which you bring in the wires.
Be sure to thread the inside nut to the conduit fitting.
2.
Route the video, control, power, and alarm wires through the conduit fitting and into the
Interface Box.
3.
Cut and trim the wires allowing for sufficient slack to their respective terminals in the
box.
1
BNC Plug (male connector)
2
Ferrite
3
Plastic cover
4
BNC Jack (female connector)
NOTICE!
If installing the dome to a drywall ceiling, allow enough wire to make the connections in the
Interface Box below the ceiling. Refer to
Figure 4.7
, for connector locations and
Table 4.1,
Page 66
, for wire connections.