40
For example, set IP LAN to 202.39.52.190 255.255.255.0
z
What can I do if PCs or workstations in the LAN can’t be connected to Internet after setting public
IP address?
Solution.
First, Please make sure that the public IP address you set is a legal public IP address, and then check
that the public IP address has not occupied by other users. Second, make sure the IP address of each
server is static and the IP Address/ Netmask/ Gateway information is completed.
And to make sure all PC is connects router with correct ISP.
z
Why can’t I set up IP Filter function in GUI?
Answer.
Due to the consideration of security, you only can set up Profile in GUI Mode, and for the LAN; it
only can be revised under the CLI Mode.
Solution.
Connect the PC to BIPAC-645 with a null modem type cable and enter CLI mode to start IP Filtering
by Telnet or Hyper-terminal.
z
What should I do if the Firmware upgraded fail in the device, and it affects me have trouble to get
into CLI & GUI screen?
Answer.
It will go through the process of Vector->Boot Code->App Code once its power on, the CLI can be
used to update Firmware as long as the Boot Code doesn’t expired.
Solution.
1. Open Hyper terminal
2. Make sure baud rate is 19200,n, 8,1,none
3. Connect the cable with both Com Port and Console Port
4. Turn on BIPAC-645
5. Choice the connection speed, then you can update the Firmware by delivery the chosen Firmware file.
z
How can I get into Router what if I forgot the password?
Answer.
If you forget the password, you can clean the password first, but all configuration will be disappeared
once the password cleaned.
Solution.
1. To get into Hyper Terminal first.
2. Make sure baud rate is 19200,n, 8,1,none
3. Turn off BIPAC-645, and connect the Console Port Cable.