58
ADVANCED USE MANUAL DD700
By setting the progressive number = 0 (zero) it is no longer
increased and is not printed.
Signal Light Management
Weight variation, Signal Lights Timeout in seconds
(OPTIONAL).
Automatic print
NO, YES
Automatic print/transmission
Automatic print
(SM)(**)
OPERATION
If you select automatic printing, it is necessary to enable OUTPUT
01 as SETPOINT.
Automatic printing in Checkweight mode (OPTIONAL)
Type
it is possible to select three types of automatic printing:
Printing stable w. in range prints the value of the net weight
when it stabilises within the weighing range.
Printing last stable w. in range prints the value of the last
stable weight detected within the weighing range.
Send last stable w. in range print saves the last stable weight
detected within the weighing range in the archive.
Transmission is carried out with PC request command (ENQ).
When the PC receives the EOT character, transmission is
complete.
Re-enabling
This establishes when the next weighing operation will be re-
enabled. If you select:
weight variation, the next weighing operation will be re-enabled
when the weight varies by the set number of divisions;
threshold divisions, the next weighing operation will be re-
enabled when the weight drops below the set number of
divisions.
In both cases the weighing operation only starts when the
weight is above the set
threshold divisions
.
Automatic printing in Manual Selector mode (OPTIONAL)
Automatic print
Select
YES
to enable automatic printing, otherwise select
NO
.
Standard, Sum Weighing, Piece Count, Manual Selector,
Weight Check, Multi-operator, Extraction during Loading,
Extraction during Unloading and Double Weighing
For all operating modes, also refer to the Using the terminal
chapter in the user manual.
Single weighing(*)(***)
Sum Weighing (*)(***)