36
ADVANCED USE MANUAL DD700
2.5
Remote commands for Input/Output management
2.5.1 Setting a single output
It is possible to set output n2 of slot n1 using command:
SO n1 n2 <CR>
where:
n1 is 1 hexadecimal character that defines the position of the output
slot;
n2 is 1 hexadecimal character that defines the output number on
slot n1.
n1 = 0 (30H) output on the terminal
n1 = 1 (31H) output on slot 1
n1 = 2 (32H) output on slot 2
n2 = 1 (31H) output number 1
n2 = 2 (32H) output number 2
n2 = 3 (33H) output number 3
n2 = 4 (34H) output number 4
2.5.2 Resetting a single output
It is possible to reset output n2 of slot n1 using command:
RO n1 n2 <CR>
where:
n1 is 1 hexadecimal character that defines the position of the output
slot;
n2 is 1 hexadecimal character that defines the output number on
slot n1.
n1 = 0 (30H) output on the terminal
n1 = 1 (31H) output on slot 1
n1 = 2 (32H) output on slot 2
n2 = 1 (31H) output number 1
n2 = 2 (32H) output number 2
n2 = 3 (33H) output number 3
n2 = 4 (34H) output number 4