26
ADVANCED USE MANUAL DD700
Note 4): it is possible to set Select Cell or Select cell data to obtain the output information relative to the
single cell or only one piece of information relative to all installed cells; setting one variable
automatically deletes the other.
By setting select cell, from 1 to number of cells, the variables take on the following meaning
Data 1 conversion value
Data 2 Absolute weight
Data 3 Relative weight
Data 4 Conversion to zero value
Data 5 temperature value
Data 6 feed voltage value
The status variable takes on the meaning of cell status
Bit
description
0x0001
The cell is disconnected
0x0002
The cell does not have a definitive address
0x0004
The cell serial number differs from the registered one
0x0008
The cell detects a low voltage
0x0001
cell temperature outside of the range -40/+80°C
0x0020
The cell is occasionally not connected
0x0040
The cell has run an internal reset
0xff80
Reserved for future use
By setting select cell data, from 1 to 6 as reported in the table below, the data variables
cell1/2/3/….n
1
cell conversion values
2
Absolute cell weights
3
Relative cell weights
4
Cell conversion to zero values
5
cell temperature values
6
cell feed voltage values
The status variable takes on the meaning of scale status
Bit
description
0x0001
At least one cell is disconnected
0x0002
At least one does not have a definitive address
0x0004
The serial number of one or more cells differs from the registered serial
number
0x0008
very different feed voltage on at least one cell
0x0010
Temperature of one cell outside of the range -40/+80°C
0x0020
None of the cells have a definitive address and the serial numbers are
different
0x0040
All cells have the correct address but the serial numbers are different
0x0080
The address of only one cell is not definitive and the serial number is
different
0x0100
Feed voltage problem on one cell
0x0200
At least one cell is occasionally not connected
0x0400
At least one cell in warm-up phase at start-up
0x0800
At least one cell has run an internal reset
0xf000
Reserved for future use