MPP: commands for MPP weights memory management (optional)
Slot1.slot2: optional cards
Note 1): the status variable contains the following indicators:
bit
meaning
15 Center zero signal (-0.25dd < gross < 0.25dd)
14 preset(1)/self-weighing(0) tare signal
13 Blocked tare
12 minimum weighing operation
11 MSB weighing extension signal (only ME)
10 overload
9 Stable weight
8 LSB weighing extension signal (only ME)
7 RFU
6 Invalid weight
5 deleted blocked tare signal (only ME)
4 Entered tare
3 RFU
2 error on scale configuration parameters
1 Failed converter
0 Approved terminal
Note 2): the variable contains some status flags
bit
meaning
15 MPP operation in progress
14 Data ready
13 RFU
12 Invalid weight error
11 Negative weight error
10 Weight not stable error
9 RFU
8 MPP memory error
7 Vehicle positioning error
6-0 RFU
Note 3): the variable is only available with multi scale terminals and contains the number of the scale
selected in the low byte; A=1, B=2,
bit
meaning
15-8 RFU
7-0 Scale number