BAFWORKS
®
INSTALLATION GUIDE
39
WWW.BIGASSSOLUTIONS.COM ©2013 DELTA T CORP. ALL RIGHTS RESERVED
BAFWORKS
®
INSTALLATION GUIDE
Fan Remote Operator Station (Optional) (cont.)
Remote operator station wiring: 575V–600V Delta M series VFDs (Powerfoil
®
X Series fans)
WARNING: The fan controllers contain high voltage capacitors that take time to discharge after removal of mains supply.
Before working on the fan controller, ensure isolation of mains supply from line inputs at the fan controller’s disconnect if
installed. Wait three (3) minutes for capacitors to discharge to safe voltage levels. Failure to do so may result in personal
injury or death. Darkened display LEDs are not an indication of safe voltage levels.
The following additional parameter changes are required for proper operation:
Jumper wire installation (shown above in yellow)
Big Ass
Solutions recommends making the parameter changes listed above prior to remote wiring or jumper wire installation. A new
jumper should be installed between terminals M4 and M5.
10k
Ω
M
AN
U
AL
AU
TO
NO
.3
.4
NO
.3
.4
U
T1
V
T2
W
T3
Brake
B1
B2
U
T1
V
T2
W
T3
Brake
B1
B2
MANUAL
AUTO
OFF
ENTER
STOP
RESET
1.5KW
VFD-M
M
0
M
4
M
5
GN
D
10
V
AV
I
GN
D
BR
O
W
N
BL
U
E
YE
LL
O
W
G
RE
EN
RE
D
W
H
IT
E
BL
A
CK
BLA
CK
RED
WHITE
GREEN
BR
OWN
BL
UE
6 conductors, 20 AWG minimum
≤100 ft (30.5 m)
Parameter
Change to
Pr.00: First Start/Stop Reference
"1" Master Freq. from 0 to +10 V
Pr.01: First Speed Reference
"1" Master Start/Stop from Ext. Terminals
Pr.41: Multifunction Input Terminal 4
"24" Control Source = Communication
Pr.42: Multifunction Input Terminal 5
"28" 2nd Source for Frequency Command
Speed Control
Knob
Mode Selection
Knob