SENSORS
7
17
ELEC
Remove:
• the fixed cap
See "FRAME 4.110" paragraph.
• the equipment support
See "ROUTINE INSPECTIONS AND ADJUSTMENTS
3.89” paragraph.
1
Disconnect:
• the ambient temperature probe
2
3
AMBIENT TEMPERATURE SENSOR
Placed near the equipment
It reads the ambient temperature and sends the value
to the equipment.
Check:
• the continuity
with the multitester positioned on PIN 1 and PIN 2
and check the table.
If the above conditions are satisfied, the lambda probe
functions, otherwise replace the component.
TOLLERANCE
Ω
° C
5
10
25
40
21 K
19 K
10 K
6 K
± 0.5 K
± 0.5 K
± 0.5 K
± 0.5 K