Copiscan 8000 Spectrum Operator Manual
Figure 29. Removing the Glass Flat
3. Push down on the right end of the glass and slide the glass to the right until you see
the edge of the glass flat on the left side. The glass flat will slightly lift away from the
metal tray for you to grasp it.
NOTE:
If the glass flat does not lift away from the metal tray, please contact Böwe Bell +
Howell technical support for further instructions at 1-800-SCAN-495.
4. Holding the left side, gently pull the glass flat towards the left. Take care not to twist
or leverage the tip where it still touches the scanner.
5. Check the glass flat for chips and scratches.
NOTE:
If the glass flat is chipped or scratched, replacement flats are available for purchase
individually (Part #S001200A) and as part of the Spectrum All-In-One Kit (Part
#S005200 through Böwe Bell + Howell Authorized Service Providers (ASPs),
Consumable Parts Resellers (CPRs) and at www.bbhscanners.com. For a complete
listing of ASPs and CPRs, please visit our website at www.bbhscanners.com.
6. Using the optic cleaning pad, carefully clean the front and back surfaces of the glass
you want to install. Inspect the glass flat after cleaning to ensure all dust and residue
has been removed.