6. Place one of the transport path cleaning sheets in the feeder and lower the skimmer.
The sheet will be pulled through the scanner.
7. Remove the sheet from the exit tray and run it through the scanner again.
8. Remove the sheet from the exit tray and flip it over.
9. Repeat steps 6 and 7.
10. Push the STOP key, and then the CLEAR key.
11. Discard the used transport cleaning sheets.
6.9
Cleaning the Page Sensors
The entry and exit page sensors may accumulate dust or small piece of paper that can
cause the miss-detection of the leading or trailing edge of the page. This causes errors to
occur within the scanner. To prevent errors from occurring, clean the page sensors once a
week, or as needed.
Take the following steps to clean the page sensors:
1. Turn OFF the scanner.
2. Remove any documents in the exit tray.
3. Open the transport with the lift-handle on the lower right side of the control panel,
opening as high as it will rise.
CAUTION:
Do not touch the page sensors with cotton swabs (or anything else) when cleaning
them. Use the transport cleaner only.
CAUTION:
Do not turn the sensor and transport cleaner can upside down or tip it sideways more
than 40° while using.
4. Clean the front sensors of the scanner using the sensor and transport cleaner. Direct
the nozzle toward each of the sensors as shown in the figures below. There are five
pairs of sensors in the entry section, located behind the holes in the stainless transport
plate at the front of the scanner.