Copiscan 8000 Spectrum Operator Manual
display. As pages exit the scanner, the paper stack decreases, and as new requests are
received from the scanning application, the paper stack increases.
5.2.2.4 STOPPED
The scanner stops when it requires an error to be cleared. When you press the STOP
button, all scanner activity halts. If there is paper in the scanner transport, it is not
ejected. Be sure to remove this paper and return it to the feeder before restarting. The
scanner displays the SCANNER STOPPED message, unless it is overwritten by an error
message.
5.2.2.5 ERROR
PROCESSING
If an error occurs during normal scanner operation, the scanner does the following:
•
Gives an audible signal (beeps)
•
Stops the transport
•
Displays an error message
5.2.2.6
Blinking Bulb Icon
Seeing this display on the control panel LCD (
) indicates a problem with the lamps.
You may continue scanning even though this message is displayed, however image
quality may be affected.
Please refer to Section 6.11,
Cleaning and Replacing the Lamps
of this manual to replace
the lamps.
5.2.2.7
Blinking Camera Icon
Seeing this display on the control panel LCD ( ) indicates that the camera needs to be
calibrated.
You may continue scanning even though this message is displayed, however failure to
calibrate the camera may affect image quality.
Please refer to Section 6.5,
Calibrating the Camera
of this manual to calibrate the
camera.
5.2.2.8 COVER
OPEN
Close Cover
Auto Feed
The side access panel and the transport must be closed before operating the scanner. The
control panel warns you if the side cover or the transport is open. The side access panel
cannot close unless the transport is open. Take the following steps to secure the scanner:
1. Open the transport.
2. Close the side access panel located on the left side of the scanner.