
Follow the same procedure for measuring the
pressure of the #1, #4, #5 mower units to
measure the pressure of the #2, #3 mower
unit reel cutter rotation circuits.
The location for installing the pressure
gauge is the #2 mower unit.
Remove the front side hydraulic hose of the
gear motor and install the pressure gauge.
Before taking measurements, set the reel
rotation/stop changeover levers of the gear
motors of all mower units (#1, #3, #4, and
#5) except mower unit #2 to the "Stop"
position.
The reel rotation circuit relief valve pressure
is set to 17.2 MPa (175.4 kgf/cm
2
) (2494.6
psi).
・
・
・
Hydraulic System
LM551
Hydraulic System
Page 4-47
Measurement
Summary of Contents for LM551
Page 1: ...5 Unit Reel Mower Service Manual Serial No LM551 10001 Ver 1 0 ...
Page 4: ...LM551 Introduction ...
Page 6: ...LM551 Contents ...
Page 12: ...LM551 Safety Page 1 6 Safety Signs and Instruction Signs ...
Page 38: ...LM551 Maintenance Standards and Maintenance Page 3 24 Greasing ...
Page 86: ...LM551 Hydraulic System Page 4 48 Measurement ...
Page 144: ...LM551 Electrical System Page 5 58 About The Electrical Components ...
Page 200: ...LM551 Troubleshooting Page 7 10 Mower Unit Related ...
Page 212: ...LM551 Reference Page 8 12 List of Consumables ...