Reel Rotation Solenoid Valve Operation
Front mower rotation solenoid
The hydraulic circuit is switched with the
signal from the terminal relay and relay 8/
unit position detection, to control the front
mower unit reel cutter rotation.
The operation of this solenoid opens the
hydraulic path and the front mower unit
reel cutter rotates.
Rear mower rotation solenoid
The hydraulic circuit is switched with the
signal from the terminal relay, to control
the rear mower unit reel cutter rotation.
The operation of this solenoid opens the
hydraulic path and the rear mower unit
reel cutter rotates.
Front mower, rear mower reverse rotation
solenoid
The hydraulic circuit is switched with the
signal from the terminal relay, to control
the forward/reverse rotation of the reel
cutter.
The operation of this solenoid switches the
hydraulic circuit, to reverse the direction of
rotation when the reel cutter is rotating.
Mower Up/Down Solenoid Valve
The mower up/down solenoid valve is
installed on the rear of the #1 mower unit.
The operation of the solenoid valve switches
the hydraulic path within the mower up/down
solenoid valve to control the cylinder mounted
to the lift arm.
The up/down solenoid of all mowers controls
the down operation of all mower units, and the
#4, #5 mower up/down solenoid stops the unit
in an intermediate position during work.
1
3
2
rt75yg-001
Mower Up/Down Solenoid Valve_001
■
1.
2.
3.
1
All mower up/down solenoid
2
#4 mower up/down solenoid
3
#5 mower up/down solenoid
Note:
All three coils used for the mower up/down
solenoid valve are the same.
Mower Up/Down Solenoid Valve Operation
All mower up/down solenoid
The hydraulic circuit is switched with the
electrical signal from the terminal relay, to
control the down of all mower units.
The operation of this solenoid opens the
hydraulic path for the down circuit of all
mower units.
#4 mower, #5 mower up/down solenoid
The hydraulic circuit is switched with the
electrical signal from the terminal relay, to
control the up of #4 mower unit and #5
mower unit.
The operation of this solenoid closes the
hydraulic path to stop the #4 mower unit
and #5 mower unit moving up.
Electromagnetic Check Valve
The electromagnetic check valve is installed
under the piston pump.
It controls the cylinder mounted to the lift arm.
The hydraulic path in the electromagnetic
check valve is switched according to the
activation of the solenoid valves.
The #2, #3 mower up solenoid controls the
up/down of the rear mower unit, and is
mounted to generate a delay when the front
mower unit moves up/down.
1
5wbqoq-002
Electromagnetic Check Valve_001
1
#2,3 mower up/down solenoid
■
・
・
LM551
Electrical System
Page 5-48
About The Electrical Components
Summary of Contents for LM551
Page 1: ...5 Unit Reel Mower Service Manual Serial No LM551 10001 Ver 1 0 ...
Page 4: ...LM551 Introduction ...
Page 6: ...LM551 Contents ...
Page 12: ...LM551 Safety Page 1 6 Safety Signs and Instruction Signs ...
Page 38: ...LM551 Maintenance Standards and Maintenance Page 3 24 Greasing ...
Page 86: ...LM551 Hydraulic System Page 4 48 Measurement ...
Page 144: ...LM551 Electrical System Page 5 58 About The Electrical Components ...
Page 200: ...LM551 Troubleshooting Page 7 10 Mower Unit Related ...
Page 212: ...LM551 Reference Page 8 12 List of Consumables ...