Inspection of Relay (CA1-DC12V-N)
Remove the relay.
The normal measured resistance between
relay terminals 1 and 2 is about 80 Ω.
1
3
4
2
5
2
5
4
3
1
38jyg3-011
Inspection of Relay (CA1-DC12V-N)_001
It is normal that there is conduction
between relay terminals 3 and 5.
2
5
4
3
1
1
3
4
2
5
38jyg3-012
Inspection of Relay (CA1-DC12V-N)_002
Normal operation is when there is
conduction between relay terminals 3 and 4
and no conduction between relay terminals
3 and 5, with the battery connected to relay
terminals 1 and 2.
2
5
4
3
1
1
3
4
2
5
38jyg3-013
Inspection of Relay (CA1-DC12V-N)_003
1.
2.
3.
4.
Terminal Relay
The terminal relay controls the following.
Reel cutter rotation direction
Up/down of all mower units
Position of #4, #5 mower unit
The operating condition can be determined by
checking the illumination of the LEDs.
Two terminal relays of four circuits each are
used.
1
2
3
a5k7kj-001
Terminal Relay_001
1
Cover
2
LED
3
Relay (G6B-2114P-US)
1.
2.
3.
LM551
Electrical System
Page 5-44
About The Electrical Components
Summary of Contents for LM551
Page 1: ...5 Unit Reel Mower Service Manual Serial No LM551 10001 Ver 1 0 ...
Page 4: ...LM551 Introduction ...
Page 6: ...LM551 Contents ...
Page 12: ...LM551 Safety Page 1 6 Safety Signs and Instruction Signs ...
Page 38: ...LM551 Maintenance Standards and Maintenance Page 3 24 Greasing ...
Page 86: ...LM551 Hydraulic System Page 4 48 Measurement ...
Page 144: ...LM551 Electrical System Page 5 58 About The Electrical Components ...
Page 200: ...LM551 Troubleshooting Page 7 10 Mower Unit Related ...
Page 212: ...LM551 Reference Page 8 12 List of Consumables ...