
Mower Unit Up/Down Circuit
The up/down of the mower unit is controlled by the following electrical components.
Traveling/Working selector switch
Proximity switch /#4 mower
Proximity switch /#5 mower
Proximity switch/Up/down lever (up)
Proximity switch/Up/down lever (down)
On delay timer
Each relay
Each solenoid valve
Operating outline of electrical circuits during mower unit up/down
The operation of the proximity switch/up/down lever (up/down) operates the terminal relay and on
delay timer to control the up/down solenoid.
The operation of the on delay timer moves the rear mower unit up/down with a 0.6 second delay
after the front mower unit operates.
In operating mode, proximity switch /#4, #5 mower detection is used to control the terminal relays,
which stops the mower unit in an intermediate position.
Inspect and adjust the mower unit up/down circuit if there is a defect with the up/down operation of
the mower unit.
1.
2.
3.
4.
5.
6.
7.
8.
・
Electrical System
LM551
Electrical System
Page 5-17
Electrical Circuit Configuration
Summary of Contents for LM551
Page 1: ...5 Unit Reel Mower Service Manual Serial No LM551 10001 Ver 1 0 ...
Page 4: ...LM551 Introduction ...
Page 6: ...LM551 Contents ...
Page 12: ...LM551 Safety Page 1 6 Safety Signs and Instruction Signs ...
Page 38: ...LM551 Maintenance Standards and Maintenance Page 3 24 Greasing ...
Page 86: ...LM551 Hydraulic System Page 4 48 Measurement ...
Page 144: ...LM551 Electrical System Page 5 58 About The Electrical Components ...
Page 200: ...LM551 Troubleshooting Page 7 10 Mower Unit Related ...
Page 212: ...LM551 Reference Page 8 12 List of Consumables ...