Code 10071: “system - I2C error reading Audio DSP temperature” (Error)
Situation
Solution
There was a problem with
the temperature sensor that
monitors the Audio DSP
temperature.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10072: “system - I2C error reading ICP FPGA temperature” (Error)
Situation
Solution
There was a problem with
the temperature sensor that
monitors the ICP FPGA
temperature.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10073: “system - I2C error reading IMB FPGA temperature” (Error)
Situation
Solution
There was a problem with
the temperature sensor that
monitors the IMB FPGA
temperature.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10074: “system - I2C error reading Power PC temperature” (Error)
Situation
Solution
There was a problem with
the temperature sensor
that monitors the processor
temperature.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10075: “system - HDD power error” (Error)
Situation
Solution
The power monitor detected
a fault on the Hard disk
power circuit.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10076: “system - Video Mezzanine FPGA version mismatch” (Warning)
Situation
Solution
The
fi
rmware version on the
Video Mezzanine add-on
board does not match the
ICMP software package.
Re-install the ICMP software package. If the problem persists, escalate
the issue.
Code 10501: “ICMP - unexpected error” (Error)
Situation
Solution
The operation has failed for
an unexpected reason.
Retry the operation. Restart the projector if the error still occurs. If
the problem persists, escalate the issue including a log package from
the system.
The ICMP reports a default
error status.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
24
R5906594 ICMP 09/11/2016
Summary of Contents for ICMP
Page 1: ...ICMP Service Manual DP Alchemy R5906594 05 09 11 2016 ...
Page 4: ......
Page 6: ...Table of contents 2 R5906594 ICMP 09 11 2016 ...
Page 18: ...2 General 14 R5906594 ICMP 09 11 2016 ...
Page 20: ...3 Preventative maintenance actions 16 R5906594 ICMP 09 11 2016 ...
Page 70: ...4 Troubleshooting 66 R5906594 ICMP 09 11 2016 ...
Page 88: ...5 ICMP service procedure 84 R5906594 ICMP 09 11 2016 ...