4. Troubleshooting
Code 10017: “formatter - sequence
fi
le checksum error” (Error)
Situation
Solution
The sequence
fi
le is
corrupted.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system. An update of the ICMP (in
the same version or in a more recent version) can help restore the
con
fi
guration
fi
les.
Code 10018: “formatter - DMD
fi
le mismatch” (Error)
Situation
Solution
The selected DMD
fi
le does
not match the used DMD.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10019: “formatter - sequence
fi
le mismatch” (Error)
Situation
Solution
The selected Sequence
fi
le
does not match the used
satellites.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10020: “formatter - red satellite thermal shutdown” (Error)
Situation
Solution
The satellite is in shutdown
due to over temperature.
Check the dust
fi
lters, check the fan speeds in communicator. If the
problem persists, escalate the issue including a log package from the
system.
Code 10021: “formatter - red satellite offset under voltage” (Error)
Situation
Solution
The offset voltage on the
satellite is too low.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10022: “formatter - red satellite reset under voltage” (Error)
Situation
Solution
The reset voltage on the
satellite is too low.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10023: “formatter - red satellite bias under voltage” (Error)
Situation
Solution
The bias voltage on the
satellite is too low.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10024: “formatter - red satellite con
fi
guration error” (Error)
Situation
Solution
There was an error while
con
fi
guring the satellite.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
R5906594 ICMP 09/11/2016
19
Summary of Contents for ICMP
Page 1: ...ICMP Service Manual DP Alchemy R5906594 05 09 11 2016 ...
Page 4: ......
Page 6: ...Table of contents 2 R5906594 ICMP 09 11 2016 ...
Page 18: ...2 General 14 R5906594 ICMP 09 11 2016 ...
Page 20: ...3 Preventative maintenance actions 16 R5906594 ICMP 09 11 2016 ...
Page 70: ...4 Troubleshooting 66 R5906594 ICMP 09 11 2016 ...
Page 88: ...5 ICMP service procedure 84 R5906594 ICMP 09 11 2016 ...