4. Troubleshooting
4. TROUBLESHOOTING
About this chapter
This chapter enumerates all ICMP related error codes which can appear on the Touch Panel display of
the cinema projector or in the projector log
fi
les. Note that some codes have a warning and an error state.
Some only have an error state, others have only a warning state. In case of a “warning” the projector
remains to operate. Nevertheless, it is recommended to solve the problem which causing the “warning”
as soon as possible otherwise, the “warning” state may turn into an “error” state which will switch off the
projector consequently.
The codes are placed in ascending order to make it easier to look up the code and
fi
nd an appropriate
solution.
Overview
•
4.1
Troubleshooting checklist
Code 10003: “system - error on power good” (Error)
Situation
Solution
There is a problem with one
of the voltages.
Escalate the issue including a log package from the system.
Code 10004: “system - error on power sequencer” (Error)
Situation
Solution
The power sequencer is
failing at startup.
Escalate the issue including a log package from the system.
Code 10005: “system - error on 0.9V power” (Error)
Situation
Solution
The 0.9V power supply is not
there or is not correct.
Escalate the issue including a log package from the system.
Code 10006: “system - error on 2.5V power” (Error)
Situation
Solution
The 2,5V power supply is not
there or is not correct.
Check the cables to the satellite boards. If the problem persists,
escalate the issue including a log package from the system.
Code 10007: “system - error on 3.3V power” (Error)
Situation
Solution
The 3,3V power supply is not
there or is not correct.
Check the cables to the satellite boards. If the problem persists,
escalate the issue including a log package from the system.
R5906594 ICMP 09/11/2016
17
Summary of Contents for ICMP
Page 1: ...ICMP Service Manual DP Alchemy R5906594 05 09 11 2016 ...
Page 4: ......
Page 6: ...Table of contents 2 R5906594 ICMP 09 11 2016 ...
Page 18: ...2 General 14 R5906594 ICMP 09 11 2016 ...
Page 20: ...3 Preventative maintenance actions 16 R5906594 ICMP 09 11 2016 ...
Page 70: ...4 Troubleshooting 66 R5906594 ICMP 09 11 2016 ...
Page 88: ...5 ICMP service procedure 84 R5906594 ICMP 09 11 2016 ...