Chapter 1: Getting Started
1–8
Please review the AutomationDirect Terms and Conditions for this product.
There is no 30-day money-back guarantee on any drive over 10 hp.
460V Class – Three Phase (continued)
Model Name: GS3-xxx
4020 4025 4030 4040 4050 4060 4075 4100
Output
Rating
Maximum Motor Output
HP
20
25
30
40
50
60
75
100
kW
15
18.5
22
30
37
45
55
75
Rated Output Current (A)
32
38
45
60
73
91
110
150
Maximum Output Voltage
Three-phase 380 to 480V (proportional to input voltage)
Rated frequency
0.1 to 400 Hz
* Input
Rating
Rated Voltage/Frequency
Three-phase,
380/400/415/440/460/480; 50/60 Hz
Rated Input Current
(A)
32
39
49
60
63
90
130
160
Voltage/Frequency Tolerance
Voltage: ± 10% Frequency: ± 5%
Short Circuit Withstand
(SCCR) (A, rms symmetrical)
5kA @ 480 VAC
10 kA @ 480 VAC
Watt Loss 100% I (W)
620
788
1290
1420
1680
2020
2910
3840
Weight (lb [kg])
26.5
[12]
26.5
[12]
26.5
[12]
77.2
[35]
77.2
[35]
77.2
[35]
116.8
[53]
116.8
[53]
* All 3-phase power sources must be symmetrical. Do not connect DURApulse drives to
grounded, center-tapped delta transformers (which are typically used for lighting circuits).
460V Class – Three Phase
Model Name: GS3-xxx
41P0
42P0
43P0
45P0
47P5
4010
4015
Output
Rating
Maximum Motor
Output
HP
1
2
3
5
7.5
10
15
kW
0.75
1.5
2.2
3.7
5.5
7.5
11
Rated Output Current (A)
2.7
4.2
5.5
8.5
13
18
24
Maximum Output Voltage
Three-phase 380 to 480V (proportional to input voltage)
Rated frequency
0.1 to 400 Hz
* Input
Rating
Rated Voltage/Frequency
Three-phase,
380/400/415/440/460/480VAC; 50/60 Hz
Rated Input Current
(A)
3.2
4.3
5.9
11.2
14
19
25
Voltage/Frequency Tolerance
Voltage: ± 10% Frequency: ± 5%
Short Circuit Withstand
(SCCR) (A, rms symmetrical)
5kA @ 480 VAC
Watt Loss 100% I (W)
70
102
132
176
250
345
445
Weight (lb [kg])
3.9
[1.759]
4.4
[1.994]
4.1
[1.857]
9.4
[4.24]
13.2
[6.002]
13.5
[6.106]
14.4
[6.525]
* All 3-phase power sources must be symmetrical. Do not connect DURApulse drives to
grounded, center-tapped delta transformers (which are typically used for lighting circuits).
DURA
PULSE
AC Drive User Manual
1st Ed. Rev. D 05/2013
Summary of Contents for DURAPULSE GS3-2010
Page 1: ...230V Class 1 50 Hp 460V Class 1 100 Hp User Manual AC Drive...
Page 2: ......
Page 6: ...w 4 DURAPULSE AC Drive User Manual 1st Ed Rev D 05 2013...
Page 8: ...Revision History DURAPULSE AC Drive User Manual h 2 BLANK PAGE...
Page 148: ...Chapter 4 AC Drive Parameters 4 80 DURAPULSE AC Drive User Manual 1st Ed Rev D 05 2013...
Page 241: ...DURAPULSE AC Drive User Manual A 1c Appendix A Accessories 1st Ed Rev D 05 2013...
Page 292: ...Appendix A Accessories DURAPULSE AC Drive User Manual A 52 BLANK PAGE 1st Ed Rev D 05 2013...
Page 314: ...Index i 8 DURAPULSE AC Drive User Manual 1st Ed Rev D 05 2013...
Page 315: ......
Page 316: ......