5–5
Parameter Memory Addresses (continued)
Parameter
Description
Hexadecimal
Modbus
Decimal *
Octal
Volts/Hertz Parameters
P2.00
Volts/Hertz Settings
0200
40513
1000
P2.01
Slip Compensation
0201
40514
1001
P2.02
Auto-torque Boost
0202
40515
1002
P2.03
Torque Compensation Time Constant
0203
40516
1003
P2.04
Mid-point Frequency
0204
40517
1004
P2.05
Mid-point Voltage
0205
40518
1005
P2.06
Min. Output Frequency
0206
40519
1006
P2.07
Min. Output Voltage
0207
40520
1007
P2.08
PWM Carrier Frequency
0208
40521
1010
P2.09**
Slip Compensation Time Constant
0209
40522
1011
P2.10
Control Mode
020A
40523
1012
Digital Parameters
P3.00
Source of Operation Command
0300
40769
1400
P3.01
Multi-function Input Terminals (DI1 - DI2)
0301
40770
1401
P3.02
Multi-function Input Terminal 3 (DI3)
0302
40771
1402
P3.03
Multi-function Input Terminal 4 (DI4)
0303
40772
1403
P3.04
Multi-function Input Terminal 5 (DI5)
0304
40773
1404
P3.05
Multi-function Input Terminal 6 (DI6)
0305
40774
1405
P3.06
Multi-function Input Terminal 7 (DI7)
0306
40775
1406
P3.07
Multi-function Input Terminal 8 (DI8)
0307
40776
1407
P3.08
Multi-function Input Terminal 9 (DI9)
0308
40777
1410
P3.09
Multi-function Input Terminal 10 (DI10)
0309
40778
1411
P3.10
Multi-function Input Terminal 11 (DI11)
030A
40779
1412
P3.11
Multi-Function Output Terminal 1 (Relay Output)
030B
40780
1413
P3.12
Multi-Function Output Terminal 2 (DO1)
030C
40781
1414
P3.13
Multi-Function Output Terminal 3 (DO2)
030D
40782
1415
P3.14
Multi-Function Output Terminal 4 (DO3)
030E
40783
1416
P3.16
Desired Frequency
0310
40785
1420
P3.17
Desired Current
0311
40786
1421
P3.18
PID Deviation Level
0312
40787
1422
P3.19
PID Deviation Time
0313
40788
1423
P3.20
Desired Frequency 2
0314
40789
1424
P3.30
Frequency Output (FO) Scaling Factor
031E
40799
1436
P3.31**
2nd Source of Operation Command
031F
40800
1437
* For Modbus Decimal addresses used with CLICK PLCs,
insert another zero as the next-to-most-significant digit, e.g., 402333 instead of 42333.
** Some parameters are available only in later firmware versions of DURA
PULSE
drives.
Refer to P9.39 and “DURA
PULSE
Parameter Summary” in Chapter 4 for more information.
Parameter can be set during RUN Mode.
Chapter 5:
DURA
PULSE
MODBUS Communications
DURA
PULSE
AC Drive User Manual
1st Ed. Rev. D 05/2013
Summary of Contents for DURAPULSE GS3-2010
Page 1: ...230V Class 1 50 Hp 460V Class 1 100 Hp User Manual AC Drive...
Page 2: ......
Page 6: ...w 4 DURAPULSE AC Drive User Manual 1st Ed Rev D 05 2013...
Page 8: ...Revision History DURAPULSE AC Drive User Manual h 2 BLANK PAGE...
Page 148: ...Chapter 4 AC Drive Parameters 4 80 DURAPULSE AC Drive User Manual 1st Ed Rev D 05 2013...
Page 241: ...DURAPULSE AC Drive User Manual A 1c Appendix A Accessories 1st Ed Rev D 05 2013...
Page 292: ...Appendix A Accessories DURAPULSE AC Drive User Manual A 52 BLANK PAGE 1st Ed Rev D 05 2013...
Page 314: ...Index i 8 DURAPULSE AC Drive User Manual 1st Ed Rev D 05 2013...
Page 315: ......
Page 316: ......