Installation and Operations Manual
AT&T Proprietary (Internal Use Only)
—97—
5. Install the battery into the PIR, observing the proper battery polarity.
NOTE
: There is a power up delay of approximately ten seconds.
6. Attach the PIR assembly onto the back plate.
NOTE
: The back plate must be mounted with the button for releasing the device on
the bottom.
6.2.7.6 Configuring the PIR
Jumper Settings
1. The 15K and High Sensitivity setting (factory default) offer the highest
level of protection. This setting allows for pet immunity for animals up to 33
pounds and is recommended for installations where no pet immunity is
required.
2. The 25K and High Sensitivity setting allow for pet immunity for animals of
up to 55 pounds while providing excellent coverage.
3. The use of the Low Sensitivity setting is not recommended when used with
the 25K setting.
Additional Detection Options
When you mount the PIR using the supplied brackets, you can adjust the angles for
additional detection options.
1. For installations that
require pet immunity
, the bracket angle must be 0
degrees.
2. For installations with no pet immunity requirement setting the bracket
angle at -9 degrees will customize the PIR for a room size of
approximately 15 feet x 15 feet.
3. For installations with no pet immunity requirement setting the bracket
angle at -18 degrees will customize the PIR for a room size of
approximately 10 feet x 10 feet.