Installation and Operations Manual
AT&T Proprietary (Internal Use Only)
—92—
6.2.6.4 Testing the Glass Breakage Detector
Functional Test
Step
Action
1.
Push the test button for two (2) seconds and release. The red LED will be on
while the button is pressed. The green LED will blink once to indicate that the
unit is in auto test mode for 90 seconds.
2.
Activate a glass break simulator in the area of the window or windows that
you are attempting to protect with the glass break detector. The glass break
detector should first acknowledge the detection of a thud sound by
illuminating the green LED and then illuminate the red LED when the unit
detects the crash portion of the glass breaking sound.
NOTE
: Use a glass break simulator such as the Intellisense Model FG-701.
Wireless Range (RF) Test
Step
Action
1.
Push and hold the test button for five (5) seconds and release. The red LED
will illuminate while the button is pressed.
2.
The green LED will blink twice to indicate that the unit is in RF test mode for
90 seconds.
6.2.6.5 Specifications—GB Detector
Glass Type/Thickness
Minimum size for all glass types is 11” x 11” (28 cm x 28 cm) square. Glass must be
framed, in a wall of the room or mounted in a barrier of 36” (91 cm) minimum width.
Glass Type
Minimum to Maximum Thickness
Plate
1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
Tempered
1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
Sealed, Insulating
1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
General Specifications
Operating Temperature
32° to 120° F (0° to 49° C)
Operating Rel. Humidity
5 to 95%, non-condensing
Operating Frequency
433.92MHz